15.6.1 Preliminaries

Before turning on the non-premixed combustion model, you must enable turbulence calculations in the Viscous Model panel.

Define $\rightarrow$ Models $\rightarrow$ Viscous...

If your model is non-adiabatic, you should also enable heat transfer (and radiation, if required).

Define $\rightarrow$ Models $\rightarrow$ Energy...

Define $\rightarrow$ Models $\rightarrow$ Radiation...

Figure  15.2.7 illustrates the types of problems that must be treated as non-adiabatic.