13.3.15 Defining Boundary Conditions for Radiation

When you set up a problem that includes radiation, you will set additional boundary conditions at inlets, exits, and walls. These inputs are described below.

Define $\rightarrow$ Boundary Conditions...



Inlet and Exit Boundary Conditions


Emissivity

When radiation is active, you can define the emissivity at each inlet and exit boundary when you are defining boundary conditions in the associated inlet or exit boundary panel ( Pressure Inlet panel, Velocity Inlet panel, Pressure Outlet panel, etc.). Enter the appropriate value for Internal Emissivity. The default value for all boundary types is 1. Alternatively, you can specify a user-defined function for emissivity. Click here to go to the UDF Manual for details.

For non-gray DO models, the specified constant emissivity will be used for all wavelength bands.

figure   

The Internal Emissivity boundary condition is not available with the Rosseland model.

Black Body Temperature

FLUENT includes an option that allows you to take into account the influence of the temperature of the gas and the walls beyond the inlet/exit boundaries, and specify different temperatures for radiation and convection at inlets and exits. This is useful when the temperature outside the inlet or exit differs considerably from the temperature in the enclosure. For example, if the temperature of the walls beyond the inlet is 2000 K and the temperature at the inlet is 1000 K, you can specify the outside-wall temperature to be used for computing radiative heat flux, while the actual temperature at the inlet is used for calculating convective heat transfer. To do this, you would specify a radiation temperature of 2000 K as the black body temperature.

Although this option allows you to account for both cooler and hotter outside walls, you must use caution in the case of cooler walls, since the radiation from the immediate vicinity of the hotter inlet or outlet almost always dominates over the radiation from cooler outside walls. If, for example, the temperature of the outside walls is 250 K and the inlet temperature is 1500 K, it might be misleading to use 250 K for the radiation boundary temperature. This temperature might be expected to be somewhere between 250 K and 1500 K; in most cases it will be close to 1500 K. (Its value depends on the geometry of the outside walls and the optical thickness of the gas in the vicinity of the inlet.)

In the flow inlet or exit panel ( Pressure Inlet panel, Velocity Inlet panel, etc.), select Specified External Temperature in the External Black Body Temperature Method drop-down list, and then enter the value of the radiation boundary temperature as the Black Body Temperature.

figure   

If you want to use the same temperature for radiation and convection, retain the default selection of Boundary Temperature as the External Black Body Temperature Method.

figure   

The Black Body Temperature boundary condition is not available with the Rosseland model.



Wall Boundary Conditions for the DTRM, and the P-1, S2S and Rosseland Models


The DTRM and the P-1, S2S, and Rosseland models assume all walls to be gray and diffuse. The only radiation boundary condition required in the Wall panel is the emissivity . For the Rosseland model, the internal emissivity is 1. For the DTRM and the P-1 and S2S models, you can enter the appropriate value for Internal Emissivity in the Thermal section of the Wall panel. The default value is 1. Alternatively, you can specify a user-defined function for emissivity. Click here to go to the UDF Manual for details.

Partial Enclosure Wall Boundary Condition for the S2S Model

When the S2S model is used, you can define a "partial enclosure" (i.e., you can disable view factor calculations for walls and inlet and exit boundaries that are not participating in the radiative heat transfer calculation). This feature allows you to save time computing the view factors and also reduce the memory required to store the view factor file during the FLUENT calculation.

To make use of this feature for walls, you can disable the Participates in S2S Radiation option in the Radiation section of the Wall panel for each relevant wall. Similarly, you can disable the view factor calculations for any inlet or exit boundary by highlighting the boundary in the Boundary Conditions panel, clicking the Set... button and turning off the Participates in S2S Radiation option (this can also be done through the define/boundary-conditions text command). You can specify the Temperature of the partial enclosure under Partial Enclosure in the Radiation Model panel (Figure  13.3.16). The partial enclosure is treated like a black body with the specified temperature.

figure   

If you change the definition of the partial enclosure by including or excluding some of the boundary zones, you will need to recompute the view factors.

figure   

The Flux Reports panel will not show the exact balance of the Radiation Heat Transfer Rate because the radiative heat transfer to the partial enclosure is not included.



Wall Boundary Conditions for the DO Model


When the DO model is used, you can model opaque walls, as discussed in
Section  13.3.6, as well as semi-transparent walls (Section  13.3.6).

You can use a diffuse wall to model wall boundaries in many industrial applications since, for the most part, surface roughness makes the reflection of incident radiation diffuse. For highly polished surfaces, such as reflectors or mirrors, the specular boundary condition is appropriate. The semi-transparent boundary condition can be appropriate, for example, when modeling for glass panes in air.

Opaque Walls

In the Radiation section of the Wall panel (Figure  13.3.21), select opaque in the BC Type drop-down list to specify an opaque wall. Opaque walls are treated as gray if gray radiation is being computed, or non-gray if the non-gray DO model is being used. If the non-gray DO model is being used, the Diffuse Fraction can be specified for each band.

Once you have selected opaque as the BC Type, you can specify the fraction of reflected radiation flux that is to be treated as diffuse. By default, the Diffuse Fraction is set to $1$, indicating that all of the radiation is diffuse. A diffuse fraction equal to $0$ indicates purely specular reflected radiation. A diffuse fraction between $0$ and $1$ will result in partially diffuse and partially specular reflected energy. See Section  13.3.6 for more details.

Figure 13.3.21: The Wall Panel Showing Radiation Conditions for an Opaque Wall
figure

You will also be required to specify the internal emissivity in the Thermal section of the Wall panel (Figure  13.3.22). For gray-radiation DO models, enter the appropriate value for Internal Emissivity. (The default value is 1.) The value that you specify will be applied to the diffuse component only. For non-gray DO models, specify a constant Internal Emissivity for each wavelength band in the Radiation tab. (The default value in each band is 1.) Alternatively, you can specify a user-defined function (UDF) for internal emissivity. Click here to go to the UDF Manual for details.

Figure 13.3.22: The Wall Panel Showing Internal Emissivity Thermal Conditions for an Opaque Wall
figure

You can also specify the external emissivity and external radiation temperature for a semi-transparent wall when the thermal conditions are set to Radiation or Mixed in the Wall panel (Figure  13.3.23). Alternatively, you can specify a UDF for these parameters.

Figure 13.3.23: The Wall Panel Showing External Emissivity and External Radiation Temperature Thermal Conditions
figure

For more information on boundary condition treatment at opaque walls,
see Section  13.3.6.

Semi-Transparent Walls

To define radiation for an exterior semi-transparent wall choose the Radiation tab in the Wall panel and then select semi-transparent in the BC Type drop-down list(Figure  13.3.24). The panel will expand to display the semi-transparent wall inputs needed to define an external irradiation flux.

Figure 13.3.24: The Wall Panel for a Semi-Transparent Wall Boundary
figure

1.   Specify the value of the irradiation flux (in W/m $^2$) under Irradiation. If the non-gray DO model is being used, a constant Irradiation can be specified for each band.

2.    Apply Irradiation Parallel to Beam is the default means of specifying the scale of irradiation flux. When active, FLUENT assumes the value of Irradiation that you specify is the irradiation flux parallel to the Beam Direction. When deselected, FLUENT instead assumes the valued specified is the flux parallel to the face normals and will calculate the resulting beam parallel flux for every face. See Figure  13.3.12 in Section  13.3.6 for details.

3.   Define the Beam Width by specifying the beam Theta and Phi extents. Beam width is specified as the solid angle over which the irradiation is distributed. The default value for beam width is $1e^-6$ which is suitable for collimated beam radiation. A beam width less than this is likely to result in zero irradiation flux.

4.   Specify the ( X,Y,Z) vector that defines the Beam Direction. Beam direction is defined by the vector of the centroid of the solid angle. Only the specular component of the irradiation flux will be applied with the specified beam direction; the diffuse irradiation flux will be applied diffusely and hemispherically to the surface.

5.   Specify the fraction of the irradiation that is to be treated as diffuse as a real number between $0$ and $1$. By default, the Diffuse Fraction is set to 1, indicating that all of the irradiation is diffuse. A diffuse fraction of $0$ treats the radiation as purely specular. If you specify a value between $0$ and $1$, the radiation is treated as partially diffuse and partially specular. If the non-gray DO model is being used, the Diffuse Fraction can be specified for each band. See Section  13.3.6 for details.

figure   

Note that the refractive index of the external medium is assumed to be 1.

figure   

If Heat Flux conditions are specified in the Thermal section of the Wall panel, the specified heat flux is considered to be only the conduction and convection portion of the boundary flux. The given irradiation specifies the incoming exterior radiative flux; the radiative flux transmitted from the domain interior to the outside is computed as a part of the calculation by FLUENT. Internal emissivity is ignored for semi-transparent surfaces.

You can also specify the external emissivity and external radiation temperature for a semi-transparent wall when the thermal conditions are set to Radiation or Mixed in the Wall panel (Figure  13.3.23). Alternatively, you can specify a user-defined function (UDF) for these parameters. Click here to go to the UDF Manual for details.

For a detailed description of boundary condition treatment at semi-transparent walls, see Section  13.3.6.

To define radiation for an interior (two-sided) semi-transparent wall, in the Wall panel choose the Radiation tab and then select semi-transparent in the BC Type drop-down list (Figure  13.3.25).

1.   Specify the Diffuse Fraction as described for the previous case.

Figure 13.3.25: The Wall Panel for an Interior Semi-Transparent Wall
figure

figure   

Note that the internal emissivity thermal condition is ignored for semi-transparent surfaces.



Solid Boundary Conditions for the DO Model


With the DO model, you can specify whether or not you want to solve for radiation in each cell zone in the domain. By default, the DO equations are solved in all fluid zones, but not in any solid zones. If you want to model semi-transparent media, for example, you can enable radiation in the solid zone(s). To do so, turn on the Participates In Radiation option in the Solid panel (Figure  13.3.26).

Figure 13.3.26: The Solid Panel
figure

figure   

In general, you should not turn off the Participates In Radiation option for any fluid zones.

See Section  13.3.6 for more information on solid semi-transparent media.



Thermal Boundary Conditions


In general, any well-posed combination of thermal boundary conditions can be used when any of the radiation models is active. The radiation model will be well-posed in combination with fixed temperature walls, conducting walls, and/or walls with set external heat transfer boundary conditions (Section  7.13.1). You can also use any of the radiation models with heat flux boundary conditions defined at walls, in which case the heat flux you define will be treated as the sum of the convective and radiative heat fluxes. The exception to this is the case of semi-transparent walls for the DO model. Here, FLUENT allows you to specify the convective and radiative portions of the heat flux separately.