[Fluent Inc. Logo] return to home search
next up previous contents index

12.19.12 Solving the $k$ Equation to Obtain Wall Boundary Conditions

In the RSM, FLUENT, by default, uses the explicit setting of boundary conditions for the Reynolds stresses near the walls, with the values computed with Equation  12.7-34. $k$ is calculated by solving the $k$ equation obtained by summing Equation  12.7-1 for normal stresses. To disable this option and use the wall boundary conditions given in Equation  12.7-35, turn off Wall B.C. from k Equation under Reynolds-Stress Options in the Viscous Model panel. (This option will not appear unless you have activated the RSM.)


next up previous contents index Previous: 12.19.11 Including the Wall
Up: 12.19 Setup Options for
Next: 12.19.13 Quadratic Pressure-Strain Model
© Fluent Inc. 2006-09-20