7.27 Fixing the Values of Variables

The option to fix values of variables in FLUENT allows you to set the value of one or more variables in a fluid or solid zone, essentially setting a boundary condition for the variables within the cells of the zone. When a variable is fixed in a given cell, the transport equation for that variable is not solved in the cell (and the cell is not included when the residual sum is computed for that variable). The fixed value is used for the calculation of face fluxes between the cell and its neighbors. The result is a smooth transition between the fixed value of a variable and the values at the neighboring cells.

figure   

You can fix values for temperature and species mass fractions only if you are using the pressure-based solver. You can fix values for velocity components only if you are using the pressure-based segregated solver. (Refer to Section  25.1.1 for information about the pressure-based segregated solver.)