7.9.2 Default Settings at Pressure Far-Field Boundaries

Default settings (in SI) for pressure far-field boundary conditions are as follows:


Gauge Pressure 0
Mach Number 0.6
Temperature 300
X-Component of Flow Direction 1
Y-Component of Flow Direction 0
Z-Component of Flow Direction 0
Turb. Kinetic Energy 1
Turb. Dissipation Rate 1