[Fluent Inc. Logo] return to home search
next up previous contents index

7.3.2 Default Settings at Pressure Inlet Boundaries

Default settings (in SI) for pressure inlet boundary conditions are as follows:


Gauge Total Pressure 0
Supersonic/Initial Gauge Pressure 0
Total Temperature 300
X-Component of Flow Direction 1
Y-Component of Flow Direction 0
Z-Component of Flow Direction 0
Turb. Kinetic Energy 1
Turb. Dissipation Rate 1


next up previous contents index Previous: 7.3.1 Inputs at Pressure
Up: 7.3 Pressure Inlet Boundary
Next: 7.3.3 Calculation Procedure at
© Fluent Inc. 2006-09-20